jactionscripters.com

Home > Socket Error > Winsock Error Wsaeacces 10013

Winsock Error Wsaeacces 10013

Contents

In some instances, it also refers to the current state of the socket—for instance, calling accept on a socket that is not listening. WinSock functions: WSAETIMEDOUT (10060) Connection timed out. A request to send or receive data was disallowed because the socket is not connected WSAESHUTDOWN (10058) Cannot send after socket shutdown . WSAENETRESET (10052) Network dropped connection on reset. news

Berkeley description: The attempted operation is not supported for the type of object referenced. WSAVERNOTSUPPORTED (10092) WINSOCK DLL Version out of range The current Winsock implementation does not support the Windows Sockets specification version requested by the application. Request refused: name server refuses to satisfy your query for policy reasons. WSAEPROTOTYPE (10041) Protocol wrong type for socket A protocol was specified that does not support the semantics of the socket type requested. news

Socket Error 10054

Typically, though, WinSock generates this error when it receives a "host unreachable" ICMP message from a router. An operation was attempted on a nonblocking socket with an operation already in progress - that is, calling connect a second time on a nonblocking socket that is already connecting, or The application has tried to determine the status of an overlapped operation which is not yet completed. Sign up for the SourceForge newsletter: I agree to receive quotes, newsletters and other information from sourceforge.net and its partners regarding IT services and products.

  • Client applications usually need not call bind at all - connect chooses an unused port automatically.
  • This error may also be returned for protocol and service queries, and means that the specified name could not be found in the relevant database. 11002 WSATRY_AGAIN Nonauthoritative host not found.
  • Why are spare wheels smaller than normal wheels?
  • Specifically, v1.1 WinSock spec notes that this error occurs if the length of the buffer is too small.
  • WinSock functions: connect(), sendto(), FD_CONNECT Additional functions: It seems odd that the v1.1 specification doesn't ascribe this error to the function bind().
  • Therefore try to disable your firewall and anti virus and run your application again.
  • On a datastream socket, the connection was reset.
  • Transposition of first matrix in crossprod in R Output Drift of an operational Integrator Why can't the second fundamental theorem of calculus be proved in just two lines? `patch:instead` removes an

WinSock functions: recv(), recvfrom(), sendto(), FD_CLOSE Additional functions: send() can also fail with WSAECONNABORTED. Date Entered: 6/17/2004 Last Updated: 6/17/2004 This is because access to raw sockets is denied in NT4 and Win2000 for non-Administrator users. This error is returned from operations on nonblocking sockets that cannot be completed immediately, for example recv when no data is queued to be read from the socket. Socket Error 10049 If you used a hostname, did it resolve to the correct address?

For instance, this error will occur if you try to run two applications that have FTP servers that both try to accept connections on port 21 (the standard FTP port). A temporary error during host name resolution and means that the local server did not receive a response from an authoritative server WSANO_RECOVERY (11003) This is a nonrecoverable error. This error is returned if the sockets implementation cannot function because the system is currently unavailable WSAVERNOTSUPPORTED (10092) Winsock.dll version out of range. https://msdn.microsoft.com/en-us/library/ee493863.aspx WSAELOOP (10062) Too many levels of symbolic links A pathname lookup involved more than eight symbolic links. (Too many links were encountered in translating a pathname.)WSAENAMETOOLONG (10063) File name too long

User suggestions: There may be too many Winsock applications running simultaneously, but this is unlikely since most network systems have many socket handles available. Winsock Error 10061 after the first failed with WSAEWOULDBLOCK). WinSock functions: WSAESHUTDOWN (10058) Cannot send after socket shutdown. WSA_QOS_EPOLICYOBJ 11025 Invalid QoS policy object.

Winsock Error 10053

This means another type of request to the name server will result in an answer. User suggestions: see WSAENETUNREACH for details WinSock functions: Additional functions: Any function that does network I/O. Socket Error 10054 By calling shutdown a partial close of a socket is requested, which is a signal that sending or receiving, or both have been discontinued. What Is A Socket Error WinSock description: Unlike Berkeley Sockets, in WinSock WSAEALREADY means that the asynchronous operation you attempted to cancel has already been canceled.

The ICMP message means that the router can't forward the IP datagram, possibly because it didn't get a response to the ARP request (which might mean the destination host is down).WSAENOTEMPTY navigate to this website more hot questions question feed lang-c about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation SSL IP*Works! Winsock description: The Windows Sockets definition of this error is very different from Berkeley Sockets. Socket Error 10054 Connection Reset By Peer

An application attempts to bind a socket to an IP address/port that has already been used for an existing socket WSAEADDRNOTAVAIL (10049) Cannot assign requested address . For example, the ARPA Internet UDP protocol cannot be specified with a socket type of SOCK_STREAM. User suggestions: This error indicates a shortage of resources on your system. More about the author WinSock only allows a single blocking operation to be outstanding per task (or thread), and if you make any other function call (whether or not it references that or any other

A service provider returned a version number other than 2.0. Winsock Error Windows 7 WSAEPROTOTYPE 10041 Protocol wrong type for socket. For example, you cannot use the ARPA Internet UDP protocol with type SOCK_STREAM.

The call has been canceled.

With datastream sockets, don't call connect() more than once (use select() or WSAAsyncSelect() to detect connection completion). The only function that takes these two explicit parameters is socket(). Identify a short story about post-apocalyptic household robots What does "M.C." in "M.C. Socket Error Codes Linux This error also occurs when you are trying to name the local socket (assign local address and port number) with bind, but Windows Sockets doesn't ascribe this error to bind, for

Related 7Robocopy permission denied6Windows 7 permission denied error3Rsync on windows: Permission Denied (13)4Remote Assistance to Windows 7 Starter Permission Denied1No ping to localhost0How to grant the permission again to users group Ping a host on the same subnet as the host you were connected to (if you know one). This normally results from an attempt to bind to an address that is not valid for the local machine. click site WSA_QOS_POLICY_FAILURE 11011 QoS policy failure.

Usually this occurs when a socket descriptor to a socket that cannot support this operation is trying to accept a connection on a datagram socket. 10046 WSAEPFNOSUPPORT Protocol family not supported. superDebug: 00010  65 6D 63 2E 63 6F 6D 20 48 65 6C 6C 6F 20 70 79  emc.com Hello py superDebug: 00020  74 68 6F 6E 2E 77 65 62 It's also possible that the local services file has an incorrect port number (although it's unlikely).