jactionscripters.com

Home > Windows 7 > Winlogon Error Incompatible Gina Dll

Winlogon Error Incompatible Gina Dll

Contents

Key Values for Displaying Information Before Logon Key value name Contents LegalNoticeCaption The string to display as the caption of the Legal Notice dialog box LegalNoticeText The string to display as Return Values for LsaLogonUser Value Meaning STATUS_SUCCESS Indicates the service completed successfully. Sets the So that Desktop state The current desktop is the system desktop. Shell Programs The shell programs inherit the environment that Userinit.exe sets up: Userinit.exe runs the shell programs named in the shell key value of the Winlogon registry key. http://jactionscripters.com/windows-7/winlogon-error-incompatible-gina-dlls.php

This allows the GINA to perform any logoff operations that may be required. Check for a Safeboot Check to see if this is a safe boot. Remote Networking Technology Support Site - http://www.remotenetworktechnology.com Windows XP Expert Zone - http://www.microsoft.com/windowsxp/expertzone On Mon, 15 Mar 2004 06:46:07 -0800, "Ralph" <> wrote: >I recently upgraded a 2000 Pro system to WlxIsLogoffOk can return FALSE to prevent the user from logging off the workstation. weblink

Msgina.dll Windows 7

Be aware that these additional threads will not receive Windows notifications. Sets the So that Desktop state The current desktop is the system desktop. FALSE Return FALSE if the message was not removed. Fix #1 (This will stop PCA from working): Backup your registry START RUN regedit go to HKEY_LOCAL_MACHINE\software\Microsoft\windows nt\currentversion\winlogon key GinaDLL needs to point to msgina.dll instead of C:\windows\system32\awgina.dll reboot Fix #2

Subscribe in a reader Recent Posts Is the server aVM July 13, 2016 How to change SRM DBpassword June 29, 2016 TSM error ANS2310E June 23, 2016 The case of the It will also return a token representing the newly logged-on user. Top of page Summary The information in this white paper expands upon and clarifies the current documentation for replacing the Microsoft Graphical Identification and Authentication Dynamic Link Library (MSGINA DLL), and Windows 10 Gina STATUS_NO_LOGON_SERVERS Indicates that no domain controllers are currently able to service the authentication request.

Reply karamvir says: September 17, 2008 at 9:36 PM hi… helpful article….but i found an entry for ginadll….which pointed to ginamsi… i deleted this ginadll entry… rebooted my system.. When FALSE is returned, Winlogon cancels the logon in process. Running the user's logon scripts. https://msdn.microsoft.com/en-us/library/windows/desktop/aa380543(v=vs.85).aspx To prevent this, download and run the file gina_upd.reg.

Winlogon calls WlxShutdown after the user has logged off and the WlxLogoff function has been called. Windows 7 Gina Registry Before Replacing the Entire GINA Before replacing the entire GINA mechanism, developers should consider the following options first. WLX_SAS_ACTION_LOCK_WKSTA Locks the workstation and waits for the next SAS. Prototype for WlxLogoff VOID WlxLogoff(   PVOID pWlxContext); Remarks Before calling WlxLogoff, Winlogon sets the desktop and workstation states as follows.

Msgina.dll Location

Submit a False Positive Report a suspected erroneous detection (false positive). https://support.microsoft.com/en-us/kb/156669 The Dispatch Table The dispatch table is always of type WLX_DISPATCH_VERSION_1_3: If the Winlogon version is less than WLX_CURRENT_VERSION, then you must do some work to pass the proper table. Msgina.dll Windows 7 FALSE Return FALSE if the GINA DLL was not initialized. Msgina.dll Location Windows 7 FALSE Return FALSE if the user was not authenticated.

If the AutoAdminLogon key value is present and contains a 1, and the AutoLogonCount key value is present and is not zero: AutoLogonCount will determine the number of automatic logons that Please join our friendly community by clicking the button below - it only takes a few seconds and is totally free. This document contains definitions of the functions that a GINA DLL must have and describes each function’s required capabilities. WlxIsLockOk Winlogon calls this function before attempting to lock the workstation. Msgina.dll Failed To Load

To display lock information, the GINA must display a dialog box that will be interrupted by a WLX_WM_SAS message. Graphical Identification and Authentication DLL (the GINA). LsaRegisterLogonProcess The LsaRegisterLogonProcess function establishes a connection to the LSA server and verifies that the caller is a logon application. news Manual Fix A Windows Server 2012–compatible application should be delivered by its manufacturer.

You can set this privilege either by using Windows NT User Manager or by calling LsaAddAccountRights. Windows Credential Providers WLX_SAS_ACTION_SHUTDOWN_REBOOT Logs the user off, shuts down the computer, and then reboots the computer. This routine needs to write out the current user name to a place where shell logoff can read it.

Possible Error Codes Error code Description STATUS_PRIVILEGE_NOT_HELD The caller does not have the SeTcbPrivilege privilege, which is required to call this function.

  • When FALSE is returned, Winlogon will terminate and the system will not boot.
  • The Essentials of Replacing the Microsoft Graphical Identification and Authentication Dynamic Link Library Published: June 07, 2001 Abstract This white paper expands upon and clarifies the current documentation for replacing the
  • The successful logon routine notifies credential managers of the successful logon and replaces the user name with the name (User Principal Name) from the certificate, so that Unlock and other variables
  • When a custom SAS is detected, Winlogon is notified by the GINA with a call to the WlxSasNotify function, and the normal SAS sequence is followed.
  • Tks, congratulations for site!!!
  • STATUS_BAD_VALIDATION_CLASS Indicates the authentication information provided is not a validation class known to the specified authentication package.
  • If the function fails, the return value is -1.
  • The GINA passes a return value to Winlogon.
  • We appreciate your feedback.

Running any user shell programs. This content is related to the documentation released by MSDN (Microsoft Developer Network) in October 2000. Workstation state The desktop is locked. Microsoft Gina Wiki WlxDisplaySASNotice Winlogon calls WlxDisplaySASNotice to display a notice when no users are logged on.

It also checks if Control+Alt+Delete is disabled. Prototype for WlxWkstaLockedSAS int WlxWkstaLockedSAS(   PVOID pWlxContext,   DWORD dwSasType); Return Values for WlxWkstaLockedSA WlxWkstaLockedSAS should return the following values. Assignment of Security to User Shell When a user logs on, the GINA creates one or more initial processes for that user, preferably by calling the Microsoft Win32 function CreateProcessAsUser and http://jactionscripters.com/windows-7/winlogon-exe-error-removal.php Prototype for WlxNetworkProviderLoad BOOL WlxNetworkProviderLoad(   PVOID pWlxContext,   PWLX_MPR_NOTIFY_INFO pNprNotifyInfo); Return Values for WlxNetworkProviderLoad Value Meaning TRUE Return TRUE if the user was authenticated.

STATUS_NAME_TOO_LONG The specified logon process name exceeds 127 bytes. Reply Venugopalan kokkodan says: October 19, 2011 at 3:21 PM This help was well recommended and its highly useful. Reply John Williams says: August 19, 2008 at 8:10 PM Pretty nice site, wants to see much more on it!🙂 Reply Kristion says: August 27, 2008 at 8:59 AM Very good STATUS_LOGON_FAILURE Indicates the logon attempt failed.

Also, many users want company-specific messages displayed before normal logon. Automatic Logon The automatic logon feature allows a Microsoft Windows NT system to: When this key value is set to 1, the last user name is not displayed in the logon Sets the So that Desktop state The current desktop is the system desktop. WlxInitialize Functions In msgina.dll WlxInitialize also allocates space for the credentials UserName, Domain, Password, and OldPassword.

WLX_SAS_ACTION_SHUTDOWN Logs the user off and shuts down the computer. WLX_SAS_ACTION_SHUTDOWN_SLEEP Puts the computer in suspend mode. Note: This function is specific to the msgina.dll and does not need to be explicitly called or implemented. This inclusion lets additional networks use Winlogon's secure desktop to gather identification and authentication information all at once during normal logon.

Remarks Before calling WlxLoggedOnSAS, Winlogon sets the desktop and workstation states as follows. Value Meaning WLX_SAS_ACTION_NONE Returns to the default desktop. Winlogon would identify the system state and call the appropriate GINA function, perhaps WlxLoggedOnSas, with the dwSasType parameter set to the third-party SAS value received from WlxSasNotify. Each network provider is a DLL that enables the operating system to interact with non-Microsoft Windows networks by implementing network-specific actions, such as making a connection and exposing a common interface

Learning resources Microsoft Virtual Academy Channel 9 MSDN Magazine Community Forums Blogs Codeplex Support Self support Programs BizSpark (for startups) Microsoft Imagine (for students) United States (English) Newsletter Privacy & cookies Don't have a SymAccount?