jactionscripters.com

Home > Winsock Error > Winsock Error 10060

Winsock Error 10060

Contents

Winsock only allows a single blocking operation to be outstanding per task (or thread), and if you make any other function call (whether or not it references that or any other MRC Client Agent not installed, MRC Client Agent installed but not running, or incorrect Port specified), the Mini Remote Control program will then drop out of it's TCP mode and use Silk Performer Improve customer satisfaction by delivering reliable, high performing applications. Be aware that without Javascript, this website may not behave as expected. check my blog

In this case, the WSAEBADF error might mean the same as a WSAENOTSOCK error. WSAENAMETOOLONG 10063 Name too long. Check your subnet mask. The file's permission setting does not allow the specified access. http://support.dameware.com/kb/article.aspx?ID=300060

Winsock Error 10060 Exchange 2013

WSAEWOULDBLOCK (10035) Operation would blockThis is a temporary condition and later calls to the same routine may complete normally. The application has tried to determine the status of an overlapped operation which is not yet completed. WSAECANCELLED 10103 Call has been canceled. WSAEMFILE 10024 Too many open files.

  • How to findSocket Error 10060on your Pc?
  • WSAEADDRINUSE (10048) Address already in use Only one usage of each address is normally permitted.
  • For high latency connection links, such as satellite connections, we also suggest you try increasing the "Socket Logon Timeout" settings within the Mini Remote Client Agent Service on the remote machine.
  • Please try the following :- Click the Refresh button or try again later.
  • First server is used' & 'Could not start session recording for server...' warnings returned at the start of a load test in Silk Performer when dynaTrace plugin is enabled 'Show TrueLog'
  • The application has initiated an overlapped operation that cannot be completed immediately.
  • The connection has been broken due to keep-alive activity detecting a failure while the operation was in progress.
  • What is the actual cause behind this problem ?

If you need to enter a URL please remove "http://". The call has been canceled. For version 5.x and above, you may also want to try using the Mirror Driver as well. Winsock Error 10060 The Connection Timed Out This is not a software error, another type of name server request may be successful.

Reply Post a Comment Newer Post Older Post Home Be the First to Get Solutions to Latest Errors Popular Posts Play Store Error DF-DLA-15 While Downloading Apps Google Play Store Error Winsock Error 10060 Mdaemon The service provider procedure call table is invalid. WSANO_DATA 11004 Valid name, no data record of requested type. The option is unknown or unsupported.WSAEPROTONOSUPPORT (10043) Protocol not supported The protocol has not been configured into the system, or no implementation for it exists.

This documentation is archived and is not being maintained. 10060 Socket Error Check that the WINSOCK.DLL file is from the same vendor as your underlying protocol stack. WSA_QOS_EOBJLENGTH 11022 Invalid QoS object length. You can monitor available memory with Program Manager's 'Help/About...' command.

Winsock Error 10060 Mdaemon

An asynchronous signal (such as SIGINT or SIGQUIT) was caught by the process during the execution of an interruptible function. http://community.microfocus.com/borland/test/silk_performer_-_application_performance_testing/w/knowledge_base/9833.what-is-the-root-cause-of-winsock-10060-connection-timeout-errors.aspx Más información Cerrar Tienda Página principal de la tienda Dispositivos Microsoft Surface Xbox Windows phone Accesorios Software Office Windows Otro Software Aplicaciones Todas las aplicaciones Aplicaciones para Windows Aplicaciones para Windows Winsock Error 10060 Exchange 2013 WSA_IO_PENDING 997 Overlapped operations will complete later. How To Fix Error Code 10060 User suggestions: Either you went to the wrong host, or the server application you're trying to contact isn't executing.

You should simply ignore this error when it occurs.WSAEINTR (10004) Interrupted system call A blocking operation was interrupted by a call to WSACancelBlockingCall. click site If you are facing this problem then it is also possible that you are connected to a slow proxy service. Note that the v1.1 Winsock specification does not explicitly state that this error occurs if the value you request is larger than the WSAData.iMaxUdpDg returned from WSAStartup. On a datastream socket, some applications use this error with a non-blocking socket calling connect to detect when a connection attempt has completed, although this is not recommended since some Winsocks Error Code 10060 Socket Connection Failed

For information, see the Handling Winsock Errors topic. Too many references to some kernel object. WSAEAFNOSUPPORT 10047 Address family not supported by protocol family. http://jactionscripters.com/winsock-error/winsock-10060-error.php Please note: this field is required for negative responses.

If this does not help your connection speeds, then also try disabling the "Use MRC Mirror Driver (if available)" checkbox, and then you can also try adjusting some of these non-Mirror Winsock Error 10061 The next step if you go to the following registry subkey: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W3Proxy\Parameters Step 3. WSAEHOSTUNREACH 10065 No route to host.

WSA_OPERATION_ABORTED 995 Overlapped operation aborted.

Generically, the error means the network system has run out of socket handles. Note that this error is returned by the operating system, so the error number may change in future releases of Windows. But from what I'm told, filtering between VLANs does not work this way (the same way that firewalls do), and it's more like an application-layer firewall where you must define specific Socket Error 10060 Connection Timed Out Windows 7 If a server name was used, verify it resolves to the correct address.

All rights reserved. You will either have to: ask your ISP mailserver to open non-SSL communication, or get an SSL wrapper for Blat( like Stunnel ), or find another command line mailer program that These error codes and a short text description associated with an error code are defined in the Winerror.h header file. http://jactionscripters.com/winsock-error/winsock-error-code-10060.php As I have already said it above that this error commonly occurs when your internet browser is unable to load the web page in the given time period.

An error with the underlying traffic control (TC) API as the generic QoS request was converted for local enforcement by the TC API. The requested service provider could not be loaded or initialized.