jactionscripters.com

Home > Winsock Error > Winsock Error Wsaeconnaborted

Winsock Error Wsaeconnaborted

Contents

Another possible reason for the WSAEACCES error is that when the bind function is called (on Windows NT 4.0 with SP4 and later), another application, service, or kernel mode driver is bound to asked 1 year ago viewed 1388 times active 1 year ago Blog Stack Overflow Podcast #93 - A Very Spolsky Halloween Special Related 10Does Windows take care of closing sockets when WSA_QOS_BAD_STYLE 11012 QoS bad style. WSAENETUNREACH 10051 Network is unreachable. news

The only function that takes these two explicit parameters is socket(). Although most of this appendix is for application developers, the User suggestions contain information that end-users and application support personnel might also find useful when an application fails. An error with the underlying traffic control (TC) API as the generic QoS request was converted for local enforcement by the TC API. User suggestions: Some network systems have commands to report statistics.

Wsaeconnaborted Software Caused Connection Abort

A general QoS error. Not what you were looking for? Berkeley description: A directory with entries other than `.'and `..' was supplied to a remove directory or rename call. This error signifies that an attempt was made to access a file (or, in some cases, a directory) in a way that is incompatible with the file's attributes.

  • Developer suggestions: Don't call bind() in a client application.
  • Alternately, you can get the local IP address by calling gethostname() followed by gethostbyname().
  • Here is a useable macro: #define MAKEWORD(low, high) ((WORD)(((BYTE)(low)) | (((WORD)((BYTE)(high))) << 8))) WinSock functions: WSAStartup(). [Go to Top] Errors in Numerical Order WSABASEERR (0) No Error WSAEINTR (10004) Interrupted system
  • Note the British spelling (with an 'S' instead of a 'Z').
  • The v1.1 WinSock specification only ascribes thirty-three of the fifty errors to any of the WinSock functions in the v1.1 for Windows Sockets specification.
  • WSA_QOS_EFLOWSPEC 11017 QoS flowspec error.
  • Handle the request as a non-fatal error (if possible), since some WinSock's can legally fail the request.
  • This is one of the most frequent errors and one of the best to encounter, since it's one of the least ambiguous.
  • WinSock description: Same as Berkeley.
  • WSAENOPROTOOPT 10042 Bad protocol option.

WSAGetLastError() and WSAIsBlocking() cannot fail. WinSock functions: gethostbyaddr(), gethostbyname(), WSAAsyncGetHostByAddr(), WSAAsyncGetHostByName(), WSAAsyncGetProtoByName(), WSAAsyncGetProtoByNumber(), WSAAsyncGetServByName(), WSAAsyncGetServByPort() Additional functions: It is strange that the asynchronous protocol and services functions can fail with this error, but the synchronous cannot. WSA_QOS_BAD_OBJECT 11013 QoS bad object. Winsock Error 10054 Usually this error is occurring when only WINS is used with separate networks.

The missing functions are getprotobyname(), getprotobynumber(), getservbyname(), and getservbyport(). Wsaeconnaborted 10053 Then I just assume my client ping timeout code will process any remaining data for the client pre-error, then remove the client information when done. you tried to connect to the wrong destination host address the server application isn't running on the destination host the server application isn't listening on the right port. http://www.sockets.com/err_lst1.htm All of the non-blocking socket methods provide ways for you to build custom timeouts: Non-blocking sockets with select() – The fifth parameter to the select() function is a timeout value.

WinSock functions: WSAENETDOWN (10050) Network is down. Winsock Error 10053 Apparently, the Windows Sockets specification left this out by oversight. WSAStartup may fail with this error if the limit has been reached.WSAEPROTONOSUPPORT (10043)Protocol not supported.The requested protocol has not been configured into the system, or no implementation for it exists. Any of the WinSock name resolution functions can fail with this error.

Wsaeconnaborted 10053

WinSock description: Same as Berkeley. http://www.ibm.com/support/docview.wss?uid=swg21548946 Get actions Tags: errordeployment-server Asked: Jun 15, 2011 at 11:20 AM Seen: 5582 times Last updated: Jun 15, '11 Follow this Question Email: Follow RSS: Answers Answers and Comments 3 People Wsaeconnaborted Software Caused Connection Abort Berkeley description: The attempted operation is not supported for the type of object referenced. Winsock Error Windows 7 For instance, you might get WSAEBADF in place of WSAENOTSOCK on a system that provides some socket and file handle equivalency.

Usually this occurs when a socket descriptor to a socket that cannot support this operation is trying to accept a connection on a datagram socket. navigate to this website WSAESTALE 10070 Stale file handle reference. An invalid QoS filter type was used. Note that the v1.1 WinSock specification does not explicitly state that this error occurs if the value you request is larger than the WSAData.iMaxUdpDg returned from WSAStartup(). Wsaeconnaborted Windows 7

There are only a few possible causes for this error: you tried to connect to the wrong port. The Windows Sockets API provides access to "low-level" API's (like the transport protocols TCP and UDP), so this error is not relevant to WinSock. Note that this error is returned by the operating system, so the error number may change in future releases of Windows. More about the author Unless other connection issues are evident, they should be ignored.

Ran out of disk quota. What Is A Socket Error WSAECONNRESET 10054 Connection reset by peer. User suggestions: Check that you have a name server(s) and/or host table configured.

TCP/IP scenario: A connection will timeout if the local system doesn't receive an (ACK)nowledgement for data sent.

Even from a legitimate closing of the client. For example, this error is returned if sendto is called with the remote address of ADDR_ANY. WinSock description: The WinSock implementation cannot function at this time, because the underlying system it uses to provide network services is currently unavailable. 10053 Wsaeconnaborted Software Caused Connection Abort It is a nonfatal error, and the operation should be retried later.

Developer suggestion: Use the sample code fragment in the WSAStartup() documentation in the v1.1 specification, which demonstrates how an application negotiates a Windows Sockets specification version. I thought I had to deal with it either on the client again, or let the socket work itself out until it realized that the connection was gone, and it would For example, the optional type SOCK_RAW might be selected in a socket call, and the implementation does not support SOCK_RAW sockets at all. http://jactionscripters.com/winsock-error/winsock-error-on.php User suggestions: see WSAHOST_NOT_FOUND for details.